0

Package Clamp Test Machine

Package Clamp Test Machine
Package Clamp Test Machine
Price And Quantity
  • 1
  • Set/Sets
    Product Description

    Specifications

    Package Clamp Test Machine 

    • Package clamp testing machine 
    • Up to ASTM D6055 
    • .PLC control 

     

    Safety protection

    Overload protection, overvoltage protection & limited position protection device  

      

    Clamp Compression Testing Method of Large Products

    • Before placing the packaged product between platens, verify that the clamp force using the clamp indicator. The indicator should be placed between the axes of the platen articulation points approximately 1/2 way up the platens.
    • .Each time the product is clamped, the force should be applied for a minimum of 15 seconds and not to exceed 1 minute.
    • Apply the clamp force on the sample with the platens resting on the floor and the front edge of the platens flush with the front of the package (see flush platen photo 4). If the package is too large for the clamps to be flush to front edge (i.e., large refrigerator, tractor etc.), clamp as close to the edge as possible.
    • Clamp the product a total of 10 times in the flush orientation.

      

     

    Clamping force

    1T

    color

    optional

    Resolution

    1/100,000

    Test Space(L x W x H)

    100x 100 x 100cm

    Test Speed

    10±3mm/min

    Weight

     around 300kg

    Power

    1#, 220V/50HZ

     

     

    Clamp Compression Testing Method of Small Products

    Before clamp testing, verify that the clamp for using the clamp force indicator. The indicator should be placed between the axes of the platen articulation points approximately 1/2 way up the platens.

     During clamp compression testing of small products, 4 samples will be utilized as outlined below.

     1. If, when oriented for clamp testing (based on the handling graphics) the sides perpendicular to the platens of a single sample ≤ 24” (61cm), then the 4 sample should be placed in a”side by side”oritentation as shown to the fig 1(with 2 samples on the bottom and 2 on the top)

     2.  If, when oriented for clamp testing the sides perpendicular to the platens of a single sample are >24” (61cm),, then the 4 samples should be placed in a top-bottom orientation as shown fig 2. If, when placed 4-high, any of the samples are completely above the top of the platens, that sample can be removed from clamping in this orientation only(fig 3 shows 3 MHC’s ready for clamp testing with the 4th sample removed from testing in this orientation)

     3 Each time the samples are clamped, the force should be applied for a minimum of 15 seconds and not to exceed 1 minute.

      

    The  Parameters

     

    Clamping force:

    50-3000kg

    Size of the clamping board:

    1200 by 1200mm

    Maximum clamping space:

    1200 by 1200 by 1200mm

    Minimum clamping space:

    400 by 1200 by 1200mm

    Clamping speed:

    5-50mm/min

    Up-down space:

    100-600mm, adjustable, can be customized

    Dimension: 3

    810 by 1900 by 2100

    Weight:

    800kg

    Power:

    380v/ 50Hz

    Control system:

    PLC programmed control

    Trade Information
    • Shenzhen China
    • Cash Against Delivery (CAD), Cash on Delivery (COD), Cash Advance (CA), Cash in Advance (CID), Cheque, Days after Acceptance (DA), Delivery Point (DP), Letter of Credit (L/C), Letter of Credit at Sight (Sight L/C), Telegraphic Transfer (T/T), Western Union, Paypal
    • 150 Per Month
    • 15 days after received the order Days
    • Each set protected with resin fiber and PP film, then put into Strong wooden case with operation manual and video inside.
    • Asia, Australia, Central America, North America, South America, Eastern Europe, Western Europe, Middle East, Africa
      Contact Us